Why is half the heating hot and half not hot?

2026-01-08 03:29:32 mechanical

Why is half the heating hot and half not hot? Full analysis of common causes and solutions

With the arrival of winter, the problem of lack of heating or partial lack of heating has become a focus of concern for many families. Recent search data on the entire Internet shows that topics related to "Heating is half hot and half not hot" have soared in popularity. The following is a collection of content and solutions that netizens are most concerned about in the past 10 days.

1. Top 5 most popular heating issues on the Internet

Why is half the heating hot and half not hot?

RankingQuestion keywordsSearch volume share
1The upper part of the radiator is not hot32%
2Some rooms are not warm due to floor heating28%
3Abnormal noise in heating pipes18%
4Heating temperature is uneven15%
5Newly installed heater is not hot7%

2. Analysis of six major reasons why the heater is not hot locally

1.Air blockage problem: The air in the radiator is not exhausted, resulting in poor hot water circulation, which is manifested as the upper part not being hot.

2.hydraulic imbalance: The system pressure is insufficient or unevenly distributed, and the remote radiator has insufficient heat.

3.clogged pipes: The accumulation of impurities caused by long-term use affects the flow of hot water.

4.Valve failure: The temperature control valve or water distributor valve is not fully opened.

5.Installation issues: The pipe slope does not meet the requirements (2-3mm slope required per meter).

6.System design flaws: The pipe diameter is too small or the circuit is too long, resulting in excessive pressure drop.

3. Solution comparison table

Question typeSelf-examination methodsolution
Air blockageThe upper part of the radiator is obviously cooler than the lower part when touchedUse the exhaust valve to release air until stable water discharge
hydraulic imbalanceThe temperature of the terminal radiator is significantly lowerAdjust the water distributor valve or install a circulation pump
clogged pipesIt has not been cleaned for many years and all radiators are not hot.Professional chemical cleaning or pulse cleaning
Valve failureValve handle cannot rotate properlyReplace the valve (it is recommended to use a copper ball valve)
Installation issuesThere is an obvious reverse slope in the pipelineRe-slope the pipe

4. Professional maintenance data reference

Maintenance itemsaverage market priceTime consuming
System exhaust50-100 yuan0.5 hours
Radiator cleaning150-300 yuan/group1-2 hours
Floor heating cleaning8-12 yuan/㎡3-4 hours
Circulation pump installation800-1500 yuan2 hours

5. Suggestions on preventive measures

1.Annual maintenance: Complete system exhaust and inspection 2 weeks before heating.

2.water quality treatment: Central heating users are advised to install filters.

3.Temperature monitoring: When the temperature difference between different rooms exceeds 3℃, it should be checked in time.

4.Smart upgrade: Installing a temperature control valve can save more than 20% energy.

6. Effective tips tested by netizens

1. Repeatedly open and close the water inlet valve 3-5 times to disperse the local air blockage.

2. Tap the radiator diagonally upward to help the air bubbles escape.

3. Floor heating users can try the "two on and two off" cycle adjustment method of the water distributor.

If there is still no improvement after 24 hours of self-treatment, it is recommended to contact professional HVAC personnel to check the system pressure (normal should be ≥0.15MPa) and flow (single-channel floor heating ≥2L/min). Heating problems in winter are related to the health of the whole family. Only by solving them in time can you have a warm winter.

Next article
  • Why is half the heating hot and half not hot? Full analysis of common causes and solutionsWith the arrival of winter, the problem of lack of heating or partial lack of heating has become a focus of concern for many families. Recent search data on the entire Internet shows that topics related to "Heating is half hot and half not hot" have soared in popularity. The following is a collection of content and solutions tha
    2026-01-08 mechanical
  • What to do if the central air conditioner leaksCentral air conditioner leakage is a common problem in many homes and businesses, which not only affects the user experience, but may also cause damage to the building structure. This article will combine the hot topics and hot content on the Internet in the past 10 days to provide you with a detailed analysis of the causes and solutions of central air conditioner leakag
    2026-01-05 mechanical
  • How to install a fresh air system: hot topics and practical guides on the InternetIn recent years, as air quality issues have received increasing attention, fresh air systems have become a popular choice for home decoration. This article combines hot topics and hot content on the Internet in the past 10 days to provide you with a detailed installation guide for fresh air systems to help you create a healthy and comfo
    2026-01-03 mechanical
  • How to deal with water seepage on the wallRecently, the problem of water seepage in houses has become the focus of many families. Especially after the rainy season, water seepage from the walls occurs frequently. This article will combine the hot topics and hot content on the Internet in the past 10 days to provide you with a detailed analysis of the causes and treatment methods of water seepage on the wall, and prov
    2025-12-31 mechanical
Recommended articles
Reading rankings
Friendly links
Dividing line