Why is half the heating hot and half not hot? Full analysis of common causes and solutions
With the arrival of winter, the problem of lack of heating or partial lack of heating has become a focus of concern for many families. Recent search data on the entire Internet shows that topics related to "Heating is half hot and half not hot" have soared in popularity. The following is a collection of content and solutions that netizens are most concerned about in the past 10 days.
1. Top 5 most popular heating issues on the Internet

| Ranking | Question keywords | Search volume share |
|---|---|---|
| 1 | The upper part of the radiator is not hot | 32% |
| 2 | Some rooms are not warm due to floor heating | 28% |
| 3 | Abnormal noise in heating pipes | 18% |
| 4 | Heating temperature is uneven | 15% |
| 5 | Newly installed heater is not hot | 7% |
2. Analysis of six major reasons why the heater is not hot locally
1.Air blockage problem: The air in the radiator is not exhausted, resulting in poor hot water circulation, which is manifested as the upper part not being hot.
2.hydraulic imbalance: The system pressure is insufficient or unevenly distributed, and the remote radiator has insufficient heat.
3.clogged pipes: The accumulation of impurities caused by long-term use affects the flow of hot water.
4.Valve failure: The temperature control valve or water distributor valve is not fully opened.
5.Installation issues: The pipe slope does not meet the requirements (2-3mm slope required per meter).
6.System design flaws: The pipe diameter is too small or the circuit is too long, resulting in excessive pressure drop.
3. Solution comparison table
| Question type | Self-examination method | solution |
|---|---|---|
| Air blockage | The upper part of the radiator is obviously cooler than the lower part when touched | Use the exhaust valve to release air until stable water discharge |
| hydraulic imbalance | The temperature of the terminal radiator is significantly lower | Adjust the water distributor valve or install a circulation pump |
| clogged pipes | It has not been cleaned for many years and all radiators are not hot. | Professional chemical cleaning or pulse cleaning |
| Valve failure | Valve handle cannot rotate properly | Replace the valve (it is recommended to use a copper ball valve) |
| Installation issues | There is an obvious reverse slope in the pipeline | Re-slope the pipe |
4. Professional maintenance data reference
| Maintenance items | average market price | Time consuming |
|---|---|---|
| System exhaust | 50-100 yuan | 0.5 hours |
| Radiator cleaning | 150-300 yuan/group | 1-2 hours |
| Floor heating cleaning | 8-12 yuan/㎡ | 3-4 hours |
| Circulation pump installation | 800-1500 yuan | 2 hours |
5. Suggestions on preventive measures
1.Annual maintenance: Complete system exhaust and inspection 2 weeks before heating.
2.water quality treatment: Central heating users are advised to install filters.
3.Temperature monitoring: When the temperature difference between different rooms exceeds 3℃, it should be checked in time.
4.Smart upgrade: Installing a temperature control valve can save more than 20% energy.
6. Effective tips tested by netizens
1. Repeatedly open and close the water inlet valve 3-5 times to disperse the local air blockage.
2. Tap the radiator diagonally upward to help the air bubbles escape.
3. Floor heating users can try the "two on and two off" cycle adjustment method of the water distributor.
If there is still no improvement after 24 hours of self-treatment, it is recommended to contact professional HVAC personnel to check the system pressure (normal should be ≥0.15MPa) and flow (single-channel floor heating ≥2L/min). Heating problems in winter are related to the health of the whole family. Only by solving them in time can you have a warm winter.