What is the reason why the excavator does not catch fire? Hot topics and in-depth analysis of the entire network
Recently, the discussion on "excavator does not catch fire" has sparked heated discussions on major engineering machinery forums and social media. Based on the hot data of the entire network for the past 10 days, we have sorted out possible causes and solutions, and helped users quickly locate problems through structured data analysis.
1. Related data on popular topics across the entire network (next 10 days)
Keywords | Search volume peak | Main discussion platform |
---|---|---|
Excavator cannot start | 5,200 times per day | Zhihu, Tieba |
Diesel engine ignition fault | 3,800 times per day | TikTok, Kuaishou |
Insufficient battery voltage | 2,900 times per day | B station, watermelon video |
Fuel system issues | 4,100 times per day | Professional maintenance forum |
2. Analysis of common causes of failures
1.Power system failure(38%)
• The battery is aging or insufficient battery capacity (voltage <12V)
• Poor line contact or fuse blown
• Damage of start relay
2.Fuel supply issues(29%)
• Diesel filter blocked
• There is air or moisture in the oil circuit
• The fuel injector is working abnormally
3.Mechanical component failure(23%)
• Starter carbon brush wear
• Insufficient cylinder compression pressure
• Turbocharger stagnation
4.Environmental factors(10%)
• Low temperature causes diesel to condense (below -10℃)
• Thin oxygen in high altitude areas
3. Troubleshooting flow diagram
step | Testing items | Normal parameters |
---|---|---|
first step | Battery voltage detection | ≥24V (large excavator) |
Step 2 | Fuel pump pressure test | 0.2-0.3MPa |
Step 3 | Cylinder compression detection | >2.5MPa |
4. References to recent hot cases
•Inner Mongolia construction site case(August 15): Colloidal deposition of the fuel system due to the use of inferior diesel, clean the fuel tank and replace the filter element.
•Popular Douyin videos(3.2 million views): Displays the temporary solution to the battery power loss problem through the "leap-on startup method".
V. Preventive suggestions
1. Recommended periods of regular maintenance:
Battery detection | Every 250 hours |
Fuel filter replacement | Every 500 hours |
Circuit system inspection | Every 1000 hours |
2. Special precautions in winter:
• Use -35# diesel (Northeast)
• Install the preheating device
• Water accumulation in the oil circuit after shutdown
Note: The statistics cycle of this article is from August 10 to August 20, 2023, covering the discussion popularity of Baidu Index, WeChat Index and construction machinery vertical platforms. If there is a complex failure, it is recommended to contact professional maintenance personnel to deal with it.